2. routine maintenance, 50 h, 100 h – Miller Electric Big 40 WG Manuel d'utilisation

Page 38: 250 h

Advertising
background image

OM-4405 Page 34

8-2.

Routine Maintenance

Follow the storage procedure in the engine owner’s manual if the unit will not be used for an
extended period.

Note

Recycle engine

fluids.

Y

Stop engine before maintaining.

.

See also Engine Manual and Mainte-
nance Label. Service unit more often if
used in severe conditions.

*

To be done by Factory Authorized
Service Agent.

8 h

Check Fluid
Levels. See
Section 4-7.

Wipe

Up

Spills.

OIL
Full

Coolant

Full

50 h

Clean Air Filter.

See Section 8-4.

Clean And

Tighten

Weld

Terminals.

1/2 in.

(13 mm)

Check Belt

Tension.

100 h

Change Oil. See

Section 8-8.

Change Oil

Filter. See

Section 8-8.

Clean And

Tighten
Battery

Connections.

Replace fuel

filter. See

Section 8-8.

Check air cleaner hoses
for cracks and loose
clamps.

250 h

Check And

Clean Spark

Arrestor. See

Section 8-3.

Check

Spark

Plugs.

Replace

Unreadable

Labels.

Advertising