13

Screw in leveling legs

4.

diamond
marking

Examine leveling legs, find diamond marking. Screw legs into

leg holes by hand, use a wrench to finish turning legs until

diamond marking is no longer visible.

Now stand the dryer on its feet. Slide the dryer until it is

close to its final location. Leave enough room to connect the

exhaust vent.

CONNECT INLET HOSE

The dryer must be connected to the cold water faucet using the

new inlet hoses. Do not use old hoses.

Turn cold water off, remove and

replace rubber washer

8.

Turn cold water faucet off and remove washer inlet hose.

Check and see if rubber washer is in the “Y” connector.

Remove old rubber washer from inlet hose and replace with

new rubber washer provided.

Attach short hose and

“Y” connector

9.

If space permits, attach the brass female end of the “Y”

connector to the cold water faucet. See figure A.

If “Y” connector cannot be attached directly to the cold water

faucet, the short hose must be used. See figure B. Attach

short hose to cold water faucet. Screw on coupling by hand

until it is seated on faucet. Then attach “Y” connector to

brass male end of the short hose. Screw on coupling by hand

until it is seated on connector.

A

B

A

B

Connect gas supply to dryer

5.

Remove red cap from gas pipe. Using a wrench to tighten,

connect gas supply to dryer. Use pipe-joint compound

on threads of all non-flared male fittings. If flexible metal

tubing is used, be sure there are no kinks.

NOTE: For LP gas connections, you must use pipe-joint

compound resistant to action of LP gas. Do not use

TEFLON

®†

tape.

A. Flared male fitting

B. Non-flared male fitting

A

B

C

D

Plan pipe fitting connection

6.

A combination of pipe fittings must be used to connect dryer

to existing gas line. A recommended connection is shown.

Your connection may be different, according to supply line

type, size, and location.

A. 3/8" flexible gas connector

B. 3/8" dryer pipe

C. 3/8" to 3/8" pipe elbow

D. 3/8" pipe-to-flare adapter fitting

A

B

Open shut-off valve

7.

Open shut-off valve in supply line; valve is open when handle

is parallel to gas pipe. Then, test all connections by brushing

on an approved noncorrosive leak-detection solution.

Bubbles will show a leak. Correct any leaks found.

A. Closed valve

B. Open valve

MAKE GAS CONNECTION

†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.

Advertising