Warning, Install vent system, Install leveling legs – Maytag W10240585B-SP Manuel d'utilisation

Page 12: Vent system chart, Install exhaust hood, Prepare dryer for leveling legs, Connect vent to exhaust hood

Advertising
background image

12

Vent system chart

Number of

90° elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

INSTALL VENT SYSTEM

12" min.

(305 mm)

12" min.

(305 mm)

Install exhaust hood

1.

Install exhaust hood and use caulking compound to seal

exterior wall opening around exhaust hood.

Prepare dryer for leveling legs

3.

To avoid damaging floor, use a large flat piece of cardboard

from dryer carton; place under entire back edge of dryer.

Firmly grasp dryer body (not console panel) and gently lay

dryer down on cardboard.

INSTALL LEVELING LEGS

WARNING

Excessive Weight Hazard

Use two or more people to move and install dryer.
Failure to do so can result in back or other injury.

Connect vent to exhaust hood

2.

Vent must fit over the exhaust hood. Secure vent to exhaust

hood with 4" (102 mm) clamp. Run vent to dryer location

using straightest path possible. Avoid 90° turns. Use clamps

to seal all joints. Do not use duct tape, screws, or other

fastening devices that extend into interior of vent to secure

vent, because they can catch lint.

The Vent system chart provides venting requirements that will

help achieve best drying performance.

NOTE: Side and bottom exhaust installation have a 90° turn

inside the dryer. To determine maximum exhaust length, add

on 90° turn to the chart.

Determine vent length and elbows needed for best

drying performance:

Use following Vent system chart to determine type of vent

material and hood combinations acceptable to use.
NOTE: Do not use vent runs longer than those specified

in Vent system chart.
Exhaust systems longer than those specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times

and increased energy usage.

Advertising