VENTING REQUIREMENTS

WARNING

Fire Hazard

Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death

or fire.

WARNING:

To reduce the risk of fire, this dryer MUST BE

EXHAUSTED OUTDOORS.

IMPORTANT:

Observe all governing codes and ordinances.

Dryer exhaust must not be connected into any gas vent,

chimney, wall, ceiling, attic, crawlspace, or a concealed space

of a building. Only rigid or flexible metal vent shall be used for

exhausting.

Rigid metal vent:

Recommended for best drying performance and to prevent

crushing and kinking.

Flexible metal vent:

(Acceptable only if accessible to clean)

Must be fully extended and supported in final dryer location.

Remove excess to avoid sagging and kinking that may

result in reduced airflow and poor performance.

Do not install in enclosed walls, ceilings, or floors.

The total length should not exceed 7

3

/

4

ft. (2.4 m).

NOTE:

If using an existing vent system, clean lint from entire

length of the system and make sure exhaust hood is not plugged

with lint. Replace plastic or metal foil vents with rigid metal or

flexible metal vents. Review Vent system chart and if necessary,

modify existing vent system to achieve best drying performance.

Only a 4" (102 mm) heavy metal exhaust

vent and clamps may be used.

Do not use plastic or metal foil vent.

Exhaust hoods:

Must be at least 12" (305 mm) from ground or any object

that may obstruct exhaust (such as flowers, rocks, bushes,

or snow).

Elbows:

45° elbows provide better airflow than 90° elbows.

Good

Better

Clamps:

Use clamps to seal all joints.

Exhaust vent must not be connected or secured with screws

or other fastening devices that extend into interior of duct

and catch lint. Do not use duct tape.

Improper venting can cause moisture and lint to collect
indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper,

carpets, etc.
Housecleaning problems and health problems.

Vent products can be purchased from your dealer. For more

information, see “Assistance or Service” section in your Use and

Care Guide.

4"

(102 mm)

4"

(102 mm)

B

A

4"

(102 mm)

2½"

(64 mm)

C

Recommended styles:

A. Louvered hood

B. Box hood

Acceptable styles:

C. Angled hood

INSTALLATION INSTRUCTIONS