Installation instructions, Exhausting the dryer (cont.) warning, Example only – GE PROFILE DPGT650 Manuel d'utilisation

Page 26

Advertising
background image

EQUIVALENT

RIGID

NUMBER

EQUIVALENT

DUCT PIECES

LENGTH

X

USED

=

LENGTH

Rigid Metal

1 Ft.

X

(4)

=

4 Ft.

Ducting
(Preferred)

Elbows

10 Ft.

X

(3)

=

30 Ft.

(90°/45°)

Turns Less

2 Ft.

X

(1)

=

2 Ft.

Than 4 Ft.

Rigid Ducting

1 Ft.

X

(5)

=

5 Ft.

4

″ Wall Cap

5 Ft.

X

(1)

=

5 Ft.

Total Ductwork Length

=

46 Ft.

TOTAL MUST BE LESS THAN OR EQUAL TO 90 FT.

Installation Instructions

26

EXHAUSTING THE DRYER (cont.)

WARNING

USE ONLY METAL 4

DUCT. DO NOT USE

DUCT LONGER THAN SPECIFIED IN THE EXHAUST
LENGTH TABLE.

Ducting longer than 90 equivalent feet will:

Increase the drying times and the energy cost.
Reduce the dryer life.
Accumulate lint, creating a potential fire hazard.

EXAMPLE ONLY

The following chart describes an example of one
possible ductwork installation.

The correct exhaust installation is your
responsibility.

Problems due to incorrect installation are not
covered by the warranty.

The length of the exhaust system depends upon
the type of duct, number of turns and the type of
exhaust hood (wall cap), and all conditions noted
below.

For satisfactory air movement, the total duct length
should not exceed 90 equivalent feet.

4

(10.2 cm)

TRANSITION

DUCTING

(DRYER T

O

W

ALL)

INSIDE W

ALLS/CEILING

(W

ALL T

O

W

ALL CAP)

W

ALL

CAPS

Less Than 4 Ft.