Installation Instructions

25

CONNECTING THE DRYER TO
HOUSE VENT

RIGID METAL TRANSITION DUCT

For best drying performance, a rigid metal

transition duct is recommended.

Rigid metal transition ducts reduce the risk of

crushing and kinking.

UL-LISTED FLEXIBLE METAL (SEMI-RIGID)
TRANSITION DUCT

If rigid metal duct cannot be used, then UL-listed

flexible metal (semi-rigid) ducting can be used
(Kit WX08X10077).

Never install flexible metal duct in walls, ceilings,

floors or other enclosed spaces.

Total length of flexible metal duct should not

exceed 8 feet (2.4 m).

For many applications, installing elbows at both

the dryer and the wall is highly recommended (see
illustrations at right). Elbows allow the dryer to sit
close to the wall without kinking and/or crushing
the transition duct, maximizing drying performance.

Avoid resting the duct on sharp objects.

UL-LISTED FLEXIBLE METAL (FOIL-TYPE)
TRANSITION DUCT

In special installations, it may be necessary to

connect the dryer to the house vent using a flexible
metal (foil-type) duct. A UL-listed flexible metal
(foil-type) duct may be used ONLY in installations
where rigid metal or flexible metal (semi-rigid)
ducting cannot be used AND where a 4

″ diameter

can be maintained throughout the entire length
of the transition duct.

In Canada and the United States, only the flexible

metal (foil-type) ducts that comply with the “Outline
for Clothes Dryer Transition Duct, Subject 2158A”
shall be used.

Never install flexible metal duct in walls, ceilings,

floors or other enclosed spaces.

Total length of flexible metal duct should not

exceed 8 feet (2.4 m).

Avoid resting the duct on sharp objects.
For best drying performance:

1. Slide one end of the duct over the clothes

dryer outlet pipe.

2. Secure the duct with a clamp.
3. With the dryer in its permanent position,

extend the duct to its full length. Allow 2

″ of

duct to overlap the exhaust pipe. Cut off and
remove excess duct. Keep the duct as straight
as possible for maximum airflow.

4. Secure the duct to the exhaust pipe with the

other clamp.

FOR TRANSITION VENTING
(DRYER TO WALL), DO:

•DO cut duct

as short as
possible and
install straight
into wall.

•DO use elbows

when turns are
necessary.

DO NOT:

•DO NOT bend or

collapse ducting.
Use elbows if
turns are
necessary.

•DO NOT use

excessive
exhaust length.
Cut duct as short
as possible.

•DO NOT crush

duct against
the wall.

•DO NOT set

dryer on duct.

Elbows