TROUBLESHOOTING

If you experience

Possible Causes

Solution

Dryer Results (cont.)

Load too hot

Load removed before cooldown

portion of cycle complete.

Allow the dryer to complete the cooldown portion of the cycle before

removing the load.

Using Timed Dry cycle with a high

temperature setting.

Select a Sensor cycle with a lower heat setting to avoid overdrying the

load.

Dryer Displaying Code Message or Indicator Is Lit

“PF” (power failure)

The drying cycle has been

interrupted by a power failure.

Press and hold START to resume the cycle, or press POWER

to select a new cycle

“L2” Diagnostic Code

(low or no line voltage

condition)

There may be a problem with your

home power supply keeping the

dryer’s heater from turning on.

The dryer will continue to run when this diagnostic code is present. Press

any key to clear the code from the display and return to the estimated

time remaining.

Try the following:
• Check to see if a household fuse has blown or circuit breaker has

tripped. Electric dryers use two household fuses or breakers. Replace

the fuse or reset the circuit breaker.

• Confirm the power cord is properly installed. Refer to Installation

Instructions for details.

Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, consult a qualified electrician.

“F# E#” (F1 E1, F3 E1,

etc.) variable service

codes.

The dryer is in need of service.

If a code beginning with an “F” appears in the display. Alternating

between F# and E#, the dryer control has detected a problem that

requires service. Call for service.

Check Vent indicator

is lit

The lint screen or vent is clogged;

the vent is crushed, kinked or has

too many turns.

The dryer will continue to run when this diagnostic code is present. Touch

any key to clear the code from the display and return to the estimated

time remaining.

Try the following:
• Clean lint screen.
• Check to see if the vent run from the dryer to the wall is crushed

or kinked.

• Confirm that the vent run from the dryer to the wall is free of lint

and debris.

• Confirm that the exterior vent exhaust hood is free of lint and debris.
• Confirm that your vent system falls within the recommended run length

and number of elbows for the type of vent you are using. Refer to “Plan

Vent System” in the Installaton Instructions for details.

Select a Timed Dry heated cycle, and restart the dryer.
If the message persists, have your entire home venting run cleaned.

Contact a venting specialist.

First try the solutions suggested here or visit our website at www.whirlpool.com/product_help –

In Canada www.whirlpool.ca for assistance and to possibly avoid a service call.

Advertising