1) Drain excess water from the tank by placing a pan under the

drain water outlet. (Fig. 1)

2) Remove the drain plug and let the water drain into the pan.

3) When the water stops draining out, replace the drain plug, and

put the tube back in with the clip pointing up.

4) Remove the pan of water.

5) Operate the unit in Fan mode to dry the interior of the unit.

ELECTRIC SHOCK HAZARD: To avoid the

possibility of personal injury, disconnect power to

the unit before installing or servicing.

Caution: To avoid installation/operation

difficulties, read these instructions thoroughly.

LOCATION

Use this portable air conditioner on a level

surface only, as inclinations greater than 3° can

cause water overflow.

Fig. 2

Flexible Exhaust Hose (13cm) & Exhaust nozzle
connector
(2 pcs)... from 17

7

/

10

(45cm) up to 53

1

/

6

” (135cm)

Adjustable window door slider kit (3 pcs).....
from 28

1

/

3

”(72cm) up to 80” (203cm)

Fixture..... (2 pcs)
Screws...(8 pcs)

NOTE: The exhaust/window kit must be

installed at all times when the unit is operating

under AIR CONDITIONING mode.

Instructions for assembling the window

adapter kit (Fig. 3).

a) Insert tube adapters through the back of the

window panel.

b) Secure each tube adapter with four screws

through the front of the window panel.

c) Insert window panel extensions into window

panel. Lightly tighten the screws in the window

panel to hold the extensions in place.

INSTALLATION ACCESSORIES

Fig. 1

Fig. 3

There should be at least 11.8” (30cm)
clearance between the unit and any other
objects or building structures, and should be
installed on a level surface. The unit does
not have to be vented outside during
Dehumidifying or Fan Only mode operation.

Flexible Exhaust Hose

Exhaust Nozzle

Connector

Fixture

Screws

Adjustable Window Slider Kit:

28 1/3” (72cm)- 80” (203cm)

Back of
Window Panel

Tube Adapters

OPERATING INSTRUCTIONS

DRAINING

EXCESS WATER

INSTALLATION

5

Advertising