3. Troubleshooting

If a minor problem occurs, it usually can be solved quite easily when the cause is found by

using the check list below.

PROBLEM

POSSIBLE CAUSE

POSSIBLE SOLUTION

Cleaner

won't run.

IMot “OIN” at cleaner. ,

Not firmly plugged in.

No voltage in wall plug.

Blown fuse or tripped breaker.

Motor Thermal Protector has

tripped.

Turn “ON” at cleaner.

Plug unit in firmly.

Check fuse or breaker.

Replace fuse or reset breaker.

Switch off and unplug the vacuum

cleaner. Leave for 30 minutes before

switching the vacuum cleaner back on.

Low suction.

Dirt container full or blocked.

Dirt container not installed properly.

Blockage in nozzle connector, hose

or wands.

Filters dirty or clogged.

Suction control valve open.

Empty dirt container.

Review dirt container replacement.

Remove blockage.

Clean or replace filters.

Close suction control valve on hand grip/

Power

nozzle

agitator

brushroll

won't run

Hose power cord not firmly plugged in.

Broken or worn belt.

Brushroll switch set to “OFF”.

Thermo Protector Activated.

Plug firmly into receptacle on cleaner

base.

Replace belt.

Set Brushroll switch to “ON”.

Switch OFF and unplug the vacuum
cleaner. Leave for 30 minutes before
switching the vacuum back on.

Nozzle

won't pick

up

Low cleaner suction.

Blockage in nozzle connector.

Agitator brushroll not running.

See section “Cleaner suction low”.

Remove blockage.

See section “Agitator brushroll won’t run”

Agitator brushroll brushes worn.

Replace brushes.

Cleaning Blockages

Low suction or pick

up may be due to
a blockage in the
system. Refer to the
following steps to

check for blockages,
continuing with
each step until the
blockage is found:

step I

Turn the vacuum

cleaner off and
unplug from the
electrical outlet.

Step II

The flexible hose

can be disconnected
from the vacuum
cleaner by pressing
the release button

on hose connec­
tor and pull out as
shown. Remove any

blockages found

then reconnect the
hose securely.

15