PRE-WIRED INSTALLATION

REPLACE COVER

REMOVE COVER

To Replace Insert
Top Tabs First

Push Bar Cover

24 Volt Bell Wire

LOCK

LIGHT

LOCK

LIGHT

LOCK

LIGHT

Drywall Anchors

Insulated
Staples

Screw 6ABx1-1/4"
(std installation)

Screw 6-32x1"
(pre-wired)

HARDWARE SHOWN ACTUAL SIZE

To prevent possible SERIOUS INJURY or DEATH from
electrocution:
• Be sure power is not connected BEFORE installing door

control.

• Connect ONLY to 24 VOLT low voltage wires.
To prevent possible SERIOUS INJURY or DEATH from a
closing garage door:
• Install door control within sight of garage door, out of reach

of children at a minimum height of 5 feet (1.5 m), and away
from ALL moving parts of door.

• NEVER permit children to operate or play with door control

push buttons or remote control transmitters.

• Activate door ONLY when it can be seen clearly, is properly

adjusted, and there are no obstructions to door travel.

• ALWAYS keep garage door in sight until completely closed.

NEVER permit anyone to cross path of closing garage door.

1

3

9

7

5

1

3

9

7

5

INSTALLATION STEP 6

Install the Control Console

Locate control console within sight of door, at a minimum
height of 5' (1.5 m) where small children cannot reach,
away from moving parts of door and door hardware. If
installing into drywall, drill 5/32" holes and use the
anchors provided. For pre-wired installations (as in new
home construction), it may be mounted to a single gang
box (Figure 1).

CAUTION: Continuous exposure of the control console
to temperatures below –22° F (–30° C) may damage the
LCD screen.

NOTE: The functional temperature range of the control
console is between –4° F (–20° C) and 122° F (50° C).
Scroll speed of the display is slower at lower
temperatures although the control console remains fully
functional.

SPECIAL NOTE: Only one 398LMC can be connected to
each garage door opener. If additional wall controls are
desired to operate the same garage door opener, it is
recommended to use model 378LMC wireless wall
control as the secondary control console.

1. Strip 7/16" (11 mm) of insulation from one end of bell

wire and connect to the two screw terminals on back of
control console by color: white wire to the W (2) and
white/red wire to the R (1) (Figure 2).

2. Remove push bar cover by gently prying at the lower/

middle portion of the cover with a small flat-head
screwdriver (Figure 1). Fasten with 6AB x 1-1/4" self-
tapping screws (drywall installation) or 6-32 x 1"
machine screws (into gang box) as follows:

Install bottom screw, allowing 1/8" (3 mm) to protrude
above wall surface.

Position bottom of control console on screw head and
slide down to secure. Adjust screw for snug fit.

Drill and install top screw with care to avoid cracking
plastic housing. Do NOT overtighten.

Replace cover by inserting top tabs first and then
snap cover in place (Figure 1).

3. (For standard installations ONLY) Run bell wire up

wall and across ceiling to motor unit. Use insulated
staples to secure wire in several places. Do NOT
pierce wire with a staple, creating a short or open
circuit.

4. Strip 7/16" (11 mm) of insulation from end of bell wire.

Connect bell wire to the quick-connect terminals on the
motor unit: white to white and white/red to red
(Figure 3).

NOTE: If you have any trouble with the operation of the
buttons, loosen the top mounting screw. DO NOT
connect the power and operate the opener at this time.
The trolley will travel to the full open position but will not
return to the close position until the sensor beam is
connected and properly aligned.

Figure 2

Figure 1

Push Bar

Light
Button

Lock
Button

Door
Control
Terminal
Screws

(BACK VIEW)

W

2

R
1

2-Conductor
Bell Wire

LOCK

LOCK

Figure 3

13

To release or insert wire,
push in tab with
screwdriver tip

Door Control
Connections

7/16" (11 mm)

Strip wire 7/16" (11 mm)