Craftsman 919.724582 Manuel d'utilisation

Page 21

Advertising
background image

21- ENG

A07187

PROBLEM

CAUSE

CORRECTION

Motor will not
run.

Fuse blown, circuit breaker
tripped.

1. Check fuse box for blown

fuse and replace as

necessary. Reset circuit

breaker. Do not use a

fuse or circuit breaker

with higher rating than

that specified for your

particular branch circuit.

2. Check for proper fuse. You

should use a time delay

fuse.

3. Check for low voltage

conditions and/or proper

extension cord.

4. Disconnect the other

electrical appliances from

circuit or operate the

compressor on its own

branch circuit.

Motor overload protection
switch has tripped.

Let motor cool off and
overload switch will
automatically reset.

Tank pressure exceeds
pressure switch "cut-in"
pressure.

Motor will start automatically
when tank pressure drops
below "cut-in" pressure of
pressure switch.

Loose electrical
connections.

Check wiring connection
inside pressure switch and
terminal box area.

Have checked by a Trained
Service Technician.

Check valve stuck open.

Remove and clean, or replace.

Possible defective motor
or starting capacitor.

Have checked by a Trained
Service Technician. Do not
operate the compressor in
the paint spray area. See
flammable vapor warning.

Paint spray on internal
motor parts.

Bleed the line by pushing the
lever on the pressure switch to
the "off" position; if the valve
does not open, replace switch.

Pressure release valve on
pressure switch has not
unloaded head pressure.

Knocking Noise. Possible defect in safety

valve.

Operate safety valve manually
by pulling on ring. If valve still
leaks, it should be replaced.

Defective check valve.

Remove and clean, or replace.

Advertising