A07187

4. Using an adjustable wrench

loosen pressure relief tube nut
at air tank and pressure switch.
Carefully move pressure relief
tube away from check valve.

5. Unscrew the check valve (turn

counterclockwise) using a 7/8"
open end wrench.

Note the

orientation for reassembly.

6. Using a screwdriver, carefully

push the valve disc up and
down.

NOTE: The valve disc

should move freely up and down
on a spring which holds the valve
disc in the closed position, if
not the check valve needs to be
cleaned or replaced.

7. Clean or replace the check

valve. A solvent, such as paint or
varnish remover can be used to
clean the check valve.

8. Apply sealant to the check valve

threads. Reinstall the check valve
(turn clockwise).

9. Replace the pressure release

tube. Tighten nuts.

10. Replace the outlet tube and

tighten nuts.

11. Perform the Break-in Procedure.

See "Break-in Procedure" in the
Operation section.

SERVICE AND ADJUSTMENTS

In closed position

disc is visible.

In open

position

nothing is

visible.

Screwdriver

To Replace or Clean Check
Valve

1. Release all air pressure from air

tank. See "To Drain Tank" in the
Maintenance section.

2. Set the On/Auto/Off lever to

"OFF" and unplug unit.

3. Using an adjustable wrench

loosen outlet tube nut at air tank
and pump. Carefully move outlet
tube away from check valve.

Outlet
Tube

Check
Valve

Nut

Pressure
Relief Tube

Nut

Risk of Unsafe

Operation. Unit

cycles automatically when power

is on. When servicing, you may

be exposed to voltage sources,

compressed air, or moving parts.

Before servicing unit unplug or

disconnect electrical supply to

the air compressor, bleed tank

of pressure, and allow the air

compressor to cool.

All maintenance and repair
operations not listed must be
performed by Trained Service
Technician.