Before Starting

Break-in instructions

Risk of Unsafe

Operation. Serious

damage may result if the following

break-in instructions are not

closely followed.
This procedure is required

before the

air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.
1. Make sure the On/Auto/Off lever

is in the "OFF" position.

NOTE: If quick connect is installed,
pull coupler back until it clicks to
prevent air from escaping through the
quick connect.
2. Plug the power cord into the

correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)

3. Open the drain valve fully

(counter-clockwise) to permit
air to escape and prevent air
pressure build up in the air tank
during the break-in period.

4. Move the On/Auto/Off lever

to "ON/AUTO" position. The
compressor will start.

13- ENG

A07187

Cooling System (not shown): This

compressor contains an advanced

design cooling system. At the heart of

this cooling system is an engineered

fan. It is perfectly normal for this fan

to blow air through the vent holes

in large amounts. You know that the

cooling system is working when air is

being expelled.
Air Compressor Pump: Compresses

air into the air tank. Working air is

not available until the compressor has

raised the air tank pressure above

that required at the air outlet.
Drain Valve: The drain valve is

located at the base of the air tank

and is used to drain condensation at

the end of each use.

Check Valve: When the air

compressor is operating, the check

valve is "open", allowing compressed

air to enter the air tank. When the

air compressor reaches "cut-out"

pressure, the check valve "closes",

allowing air pressure to remain inside

the air tank.
Pressure Release Valve: The

pressure release valve located on

the side of the pressure switch, is

designed to automatically release

compressed air from the compressor

head and the outlet tube when the

air compressor reaches "cut-out"

pressure or is shut off. The pressure

release valve allows the motor to

restart freely. When the motor stops

running, air will be heard escaping

from this valve for a few seconds.

No air should be heard leaking when

the motor is running, or continuous

leaking after unit reaches "cut-out"

pressure.

Drain

Valve

Check

Valve

Pressure

Release

Valve

How to Use Your Unit

How to Stop:

1. Set the On/Auto/Off lever to

"OFF".

Advertising