Installation Manual 9

- If the design of the vehicle does not allow you to install a roof exhaust vent, install an upper

side-wall exhaust vent.

The refrigerator is 23.7 in. min. to 24.0 in. max. from the rear of the breaker

to the rear of the condenser [22] and 54.1 in. min. to 54.4 in. max. from the

bottom of the refrigerator to the bottom of the refrigerator condenser [23]

(See Art01678).

- Install the upper side-wall exhaust vent [24] (See Art01679 and Art01680).

- Make sure the distance [25] from the bottom of the enclosure to the top of the rough

opening for the upper exhaust vent is at least 62 inches.

- Align the upper exhaust vent horizontally above the lower intake vent [9] of the

refrigerator.

- To prevent stagnant hot air in the area above the refrigerator, install an aluminum or

galvanized steel sheet baffle [13] between the top of the refrigerator and the top of

the upper exhaust vent.

- Make sure there is less than 1/4 inch clearance between the baffle and the top

of the refrigerator [16] and that the baffle overlaps the refrigerator 1 inch or

less.

- Make sure that the baffle is against the wall of the vehicle at the top of the

upper exhaust vent and 1/4 inch or less from the top of the opening for the

upper exhaust vent [15].

- Make sure the baffle is the full width of the inside of the enclosure

- When using an upper side-wall exhaust vent:

- If the depth of the enclosure is more than 24 inches and less than 26 inches [27], install a bent aluminum or galvanized steel

sheet baffle [26] to the rear of the enclosure (See Art01679).