10

9.

When starting engine, position yourself as recommended
in Figure 9 and start engine according to instructions
given in engine operator’s manual.Also see operating
instructions tag located on the pressure washer.

NOTE: Always keep the throttle lever in the “Fast
position when operating the pressure washer.

How to Stop Your Pressure Washer

1.

Let engine idle for two minutes.

2.

Turn engine off according to instructions given in
engine operator’s manual.

3.

ALWAYS point gun in a safe direction and squeeze
spray gun trigger to release retained high water
pressure.

IMPORTANT: Spray gun traps high water pressure, even
when engine is stopped and water is disconnected.

4.

Engage trigger lock on spray gun when not in use.

Figure 9 - Recommended Starting Position

• ALWAYS point gun in safe direction and squeeze spray gun

trigger, to release pressure and avoid kickback each time,
before starting engine.

• When starting engine, pull cord slowly until resistance is felt

and then pull rapidly to avoid kickback.

• After each starting attempt, where engine fails to run, always

point gun in safe direction and squeeze spray gun trigger to
release high pressure.

• Firmly grasp spray gun with both hands when using high

pressure spray to avoid injury when gun kicks back.

Rapid retraction of starter cord (kickback) will
pull hand and arm toward engine faster than
you can let go.
Broken bones, fractures, bruises or sprains could
result.

WARNING

• DO NOT touch hot surfaces and avoid hot exhaust gases.

• Allow equipment to cool before touching.

• Keep at least 5 ft. (152 cm) clearance on all sides of pressure

washer including overhead.

• Code of Federal Regulation (CFR) Title 36 Parks, Forests, and

Public Property require equipment powered by an internal
combustion engine to have a spark arrester, maintained in
effective working order, complying to USDA Forest service
standard 5100-1C or later revision. In the State of California a
spark arrester is required under section 4442 of the California
Public resources code. Other states may have similar laws.

Running engines produce heat.Temperature of
muffler and nearby areas can reach or exceed
150°F (65°C).
Severe burns can occur on contact.
Exhaust heat/gases can ignite combustibles,
structures or damage fuel tank causing a fire.

WARNING

• Keep high pressure hose connected to pump and spray gun

while system is pressurized.

• ALWAYS point gun in safe direction and squeeze spray gun

trigger, to release high pressure, every time you stop engine.
Engage trigger lock when not in use.

The high pressure stream of water that this
equipment produces can pierce skin and its
underlying tissues, leading to serious injury and
possible amputation.
Spray gun traps high water pressure, even when
engine is stopped and water is disconnected,
which can cause injury.

WARNING