HANDLE INSTALLATION AND DOOR ALIGNMENT

For the door to close properly, it is necessary to maintain a

minimum space of

9

32

” (7mm) between the door and cabi-

net flange (See Figure 6). This space can be adjusted by

adjusting the top and bottom hinge adapter brackets.

NOTE

Door Alignment Procedure

The door should be parallel to the sides and top of the ap-

pliance. If alignment is necessary the door may be adjusted

by loosening the 2 screws which secure the hinge adapter

brackets on the top and bottom of the door and adjusting

the door side to side. Use a

5

32

” allen wrench for this pro-

cedure. (See Figure 6 below). When finished aligning the

door, tighten the screws securely.

Handle Installation (Solid Door Models)

1. Remove the handle, (2) screws, and

5

32

” allen wrench

from the bag shipped inside the cabinet.

2. Locate handle opposite the hinges and secure in place

using the (2) screws and the allen wrench.

(See Figure 5).

Screws

Handle

Figure 5

Right hand hinged

door shown

Figure 6

Hinge adapter bracket

located on the top and bot-

tom of the door.

Remove top

hinge pin to re-

move the door.

Door should be

parallel to top

and sides of

appliance.

9

32

(7.1mm)