APPENDIX A, ADDITIONAL MICROSENTRY II FEATURES

Information Menu / Lockout Key

To access the information menu, press the SET key, and

immediately release it.

In the information menu, a 2 or 3 digit code will be dis-

played representing each entry in the information menu.

The first code displayed will be t1. With each sequential

press and release of the SET key, the following codes will

appear in this order: t1, t2, thi, tLo, cnd, FrM, and Loc.

(The t2 code only appears on the refrigerator).

To view the value of each code, press and hold the SET

key after the desired code is displayed. Additionally,

the WARMER and COLDER keys may be used to scroll

through the menu. To exit the information menu, press

the ON/OFF key, or wait for several seconds with no key

presses.

1) Current Interior Temperature (tI): While

tl is shown on the screen press and hold the

“SET” key to display the current interior tem-

perature.

2) Defrost Sensor Temperature (t2) refrig-

erator only: While t2 is shown on the screen

press and hold the "SET" key to display the

temperature of the defrost sensor.

3) Maximum Stored Temperature (thi): While

thi is shown on the screen, press and hold the

“SET” key to display the maximum recorded

temperature. The temperature is updated every 5 minutes.

To reset the maximum temperature; continue to hold the

SET key, then press and release the ON/OFF key to reset

the maximum temperature. The maximum temperature will

be reset to the current compartment temperature.

It is recommended that thi be reset after the initial pull-

down (24 hours after power on) to clear any residual

values.

4) Minimum Stored Temperature (tLO):

While tLo is shown on the screen, press and

hold the “SET” key to display the minimum

recorded temperature. The temperature is updated every

5 minutes. Continue to hold the SET key then, press and

release the ON/OFF key to reset the minimum temperature.

The minimum temperature will be reset to the current com-

partment temperature. It is recommended that tLo be reset

after the initial pull down (24 hours after power on) to clear

any residual values.

5) Total Operating Time of the Condenser

Since the Last Cleaning (cnd): The operating

time of the condenser since the last cleaning.

The control monitors the operating time of the condenser

fan to determine when the condenser is in need of being

cleaned. While cnd is displayed on the screen, press and

hold SET key to view the value of cnd. The value shown

is the number of weeks the condenser has been operating.

To reset cnd, continue to hold the SET key then press and

release the ON/OFF key. When the control recommends

the condenser be cleaned, a reminder will be displayed on

the screen (see Alarm Codes.) To clear the alarm code, re-

set the value in cnd following the instructions printed above.

6) Firmware Version (FrM): While FrM is

shown on the screen press and hold the "SET"

key to display the version of the firmware.

7) Keypad Lockout Feature (Loc): This fea-

ture is used to prevent accidental changes to

the set temperature, or accidentally turning the unit off.

While Loc is displayed on the screen, press and hold the

SET key.

If “No” is displayed, Lockout feature is off,

and all keys are enabled. If “Yes” is dis-

played, Lockout feature is ON. The ability to turn the unit

on and off, as well as the ability to adjust set temperature

will be disabled. To change the keypad lockout setting,

continue to hold the SET key, then use the WARMER and

COLDER keys to set the desired value.