INSTALLATION INSTRUCTIONS

Venting Methods

Determine which venting method is best for your application.
Vent system can terminate either through the wall or floor.

Island Location

NOTE: For island locations, a front- or rear-mounted blower
motor can also be mounted for right or left venting if needed for
your application. Most island applications would still require the
venting to be directed down through the floor.

Built-In Cabinet Locations

Island Location - Vent System Installed Under a Concrete
Slab Using PVC Sewer Pipe

Front (Standard) Mounted Blower Motor

Rear Mounted Blower Motor

Calculating Vent System Length

3¼" x 10" (8.3 x 25.4 cm) rectangular vent is required from the
blower motor box. It can be transitioned to 6" (15.2 cm) round
vent if needed.

Maximum Length of Vent System

Front (Standard)-Mounted
Blower Motor

Rear-Mounted Blower
Motor

A. Down vent

A. Down vent
B. Left vent

C. Right vent

A

A

B

C

A

A. Wall cap
B. 6" (15.2 cm) round metal vent

C. 16" (40.6 cm) maximum
D. 6" (15.2 cm) round PVC sewer pipe

E. 6" (15.2 cm) round metal vent transition with damper

(supplied)

F. 6" (15.2 cm) round PVC coupling

G. Concrete slab

H. 6" (15.2 cm) round PVC sewer pipe

I. 6" (15.2 cm) round 90° PVC sewer pipe elbow

J. Tightly pack gravel or sand completely around pipe.

K. 6" (15.2 cm) round 90° PVC sewer pipe elbow

L. 6" (15.2 cm) round PVC coupling

M. 12" (30.5 cm) minimum

Vent

Length

6" (15.2 cm) round

35 ft (8.9 m)

3

¹⁄₄" x 10" (8.3 cm x 25.4 cm)

35 ft (8.9 m)

A

B

C

D

E

F

G

H

I

J

K

L

M

A

B

C

D

E

F

G

H

I

J

K

L

M