Cabinet Dimension

NOTES:

See cooktop manufacturer’s instructions for cooktop cutout
depth and width.

Use dimensions for vent system cutout location that applies
to your installation.

Interior mounted blower systems connect with 3

¹⁄₄" x 10"

(8.3 x 25.4 cm) rectangular or 6" (15.2 cm) round vent system.
The cutout locations for this vent system will depend on your
specific installation.

Countertop Cutout Dimensions

IMPORTANT: Countertops with a bull-nosed front edge are not recommended for these installations.

Some models require a countertop deeper than 25" (63.5 cm); see the following “Countertop Cutout Dimensions Chart.”

To avoid mistakes, it is recommended that the cooktop and vent cutouts be drawn on the countertop before making any cutouts.

See the Installation Instructions that came with your cooktop for complete cutout dimensions, location dimensions and installation
details.

A=

¹⁄₂

" (12.7 mm)

minimum

21

⁵⁄₁₆

"

(54.1 cm)

Cutouts are
for 3

¹⁄₄

" x 10"

(8.3 x 25.4 cm)
rectangular or 6"
(15.2 cm) round
vent system.

Centerline of cooktop cutout

21⁵⁄₁₆

"

(54.1 cm)

Locate power
supply junction
box at lower
left hand
rear corner
of the cabinet.

10

" (25.4 cm)

A. Downdraft vent
B. Cooktop

C. Measurement of cooktop rear overhang
D. D = Measurement of cooktop rear overhang

(C) + 1

¹³⁄₁₆

" [46.2 mm] (E)

E. 1

¹³⁄₁₆

" (46.2 mm)

F. ½" (12.7 mm) minimum

G. ¼" (6.4 mm) minimum
H. Countertop and backsplash

I. ½" (12.7 mm) minimum

A

B

C

E

H

D

I

G

F