7. Fasten the lower support legs to the cabinet floor with screws

(not provided).

8. Tighten the lower support legs screws.

Make Electrical Connections

1. Disconnect power.

2. Feed the power supply cable through the conduit connector

and into the terminal box.

3. Connect the green (or green/yellow) ground wire to the green

or yellow/green ground wire using UL listed wire connectors.
Tighten the screw on the conduit connector.

4. Connect the 2 white wires together using UL listed wire

connectors.

5. Connect the 2 black wires together using UL listed wire

connectors.

6. Replace the terminal box cover and secure with screw.

7. Reconnect power.

Check Operation

1. Push and hold the button on the top of the downdraft vent for

a few seconds. The retractable section of the downdraft vent
will rise, and the blower will start. Position the top trim over
the retractable section and snap trim into place.

Trim kits for matching your cooktop color are available from
your dealer.

For information on ordering, see the “Assistance or Service”
section.

2. Slide the control slider on the side of vent to check the

operation and speed of the blower.

3. If the blower does not operate:

Check that filter or filters are pressed in as far as they will
go.

Check that the circuit breaker has not tripped or a
household fuse blown.

4. Connect vent system to blower. Vent system must end with a

wall or roof cap. Use clamps or duct tape to seal all joints.

5. Install cooktop according to manufacturer’s instructions.

Check that rear of cooktop overlaps edge of retractable
downdraft vent by

³⁄₈" (9.5 mm). See “Countertop Cutout

Dimensions” in the “Location Requirements” section.

NOTE: To get the most efficient use from your new retractable
downdraft vent, read the “Vent System Use” section.

A. Screw (not provided)

A

WARNING

Electrical Shock Hazard

Disconnect power before servicing.

Replace all parts and panels before operating.

Failure to do so can result in death or electrical shock.

WARNING

Electrical Shock Hazard

Electrically ground blower.

Connect ground wire to green and yellow ground wire
in terminal box.

Failure to do so can result in death or electrical shock.

A. Green or green and yellow

ground wire

B. White wires
C. UL listed wire connectors

D. Black wires

E. UL listed or CSA approved

conduit connector