Tighten couplings, Attach short hose and “y” connector, Turn on cold water faucet – Whirlpool WGD8100BW Manuel d'utilisation

Page 13: Check for leaks

Advertising
background image

13

Tighten couplings

3.

Using pliers, tighten the couplings with additional

two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

Attach short hose and

“Y” connector

2.

If space permits, attach the female end of the “Y” connector

to the cold water faucet. See figure A.

If “Y” connector cannot be attached directly to the cold water

faucet, the short hose must be used. See figure B. Attach

short hose to cold water faucet. Screw on coupling by hand

until it is seated on faucet. Then attach “Y” connector to the

male end of the short hose. Screw on coupling by hand until

it is seated on connector.

Fig. A

Fig. B

Attach long hose to “Y”

connector and tighten couplings

4.

One end of the long hose has a wire mesh strainer inside the

coupling. Attach this end to the “Y” connector. Attach washer

cold inlet hose to other side of “Y” connector. Screw on

coupling by hand until it is seated on connector. Using pliers,

tighten the couplings an additional two-thirds turn.

NOTE: Do not overtighten. Damage to the coupling can result.

3

3

/

4

"

(95 mm)

11"

(279 mm)

Attach long hose to dryer fill

valve and tighten coupling

5.

Attach other end of long hose

to fill valve at bottom of dryer

back panel. Screw on coupling

by hand until it is seated on fill

valve connector. Using pliers,

tighten the couplings an additional

two-thirds turn.

NOTE: Do not overtighten. Damage

to the coupling can result.

Turn on cold water faucet

6.

Check that the water faucets are turned on.

Check for leaks

7.

Check for leaks around “Y” connector, faucets, and hoses.

Advertising