Plan vent system – Whirlpool WGD8100BW Manuel d'utilisation

Page 11

Advertising
background image

11

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best

for your installation. Two close-clearance installations are shown.

Refer to the manufacturer’s instructions.

Special provisions for mobile homes:

Exhaust vent must be securely fastened to a noncombustible

portion of mobile home and must not terminate beneath the

mobile home. Terminate exhaust vent outside.

Moblie Home Exhaust installation

A

B

A. Over-the-top installation

(also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate

installations are available for purchase. Contact your local dealer.

Over-the-Top Installation:

Part Number 4396028

Periscope Installation (For use with dryer vent to wall vent

mismatch):

Part Number 4396037 - 0" (0 mm) to 18" (460 mm) mismatch

Part Number 4396011 - 18" (460 mm) to 29" (737 mm)

mismatch

Part Number 4396014 - 29" (737 mm) to 50" (1270 mm)

mismatch

If you prefer, dryer may be converted to exhaust through

the bottom. You must contact your local dealer to have dryer

converted.

A

B

A. Standard rear offset exhaust installation

B. Bottom exhaust installation

Optional exhaust installations:

Exhaust Cover Kit (to cover unused exhaust holes):
Part Number W10186596 - all models

Bottom Exhaust Kit- Part Number 8212503

PLAN VENT SYSTEM

Recommended exhaust installations

Typical installations vent the dryer from the rear of the dryer.

Other installations are possible.

B

B

C

D

E

F

G

H

A

A. Dryer

B. Elbow

C. Wall

D. Exhaust hood

E. Clamps

F. Rigid metal or flexible metal vent

G. Vent length necessary to connect elbows

H. Exhaust outlet