CONNECT INLET HOSES

For non-steam models, skip to “Connect Vent.”

The dryer must be connected to the cold water faucet using

the new inlet hoses. Do not use old hoses.

Turn cold water off, remove and

replace rubber washer

1.

Turn cold water faucet off and remove washer inlet hose.

Check and see if rubber washer is in the “Y” connector.

Remove old rubber washer from inlet hose and replace with

new rubber washer provided.

Connect vent to exhaust hood

2.

Vent must fit over the exhaust hood. Secure vent to exhaust

hood with 4" (102 mm) clamp. Run vent to dryer location

using straightest path possible. Avoid 90° turns. Use clamps

to seal all joints. Do not use duct tape, screws, or other

fastening devices that extend into interior of vent to secure

vent, because they can catch lint.

INSTALL VENT SYSTEM

12" min.

(305 mm)

12" min.

(305 mm)

Install exhaust hood

1.

Install exhaust hood and use caulking compound to seal

exterior wall opening around exhaust hood.

†®TEFLON is a registered trademark of E.I. Dupont De Nemours and Company.

Determine vent length and elbows needed for best

drying performance:

Use following Vent System Chart to determine type of vent

material and hood combinations acceptable to use.

NOTE: Do not use vent runs longer than those specified

in Vent System Chart. Exhaust systems longer than those

specified will:

Shorten life of dryer.

Reduce performance, resulting in longer drying times

and increased energy usage.

Whirlpool Vent System Chart

Number of

90° elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

64 ft. (20 m)

54 ft. (16.5 m)

44 ft. (13.4 m)

35 ft. (10.7 m)

27 ft. (8.2 m)

58 ft. (17.7 m)

48 ft. (14.6 m)

38 ft. (11.6 m)

29 ft. (8.8 m)

21 ft. (6.4 m)

The Vent System Charts provide venting requirements that

will help achieve best drying performance.

NOTE: Bottom exhaust installations have a 90° turn inside the

dryer. To determine maximum exhaust length, add one 90° turn

to the charts.

Maytag Vent System Chart

Number of

90° elbows

Type

of vent

Box/louvered

hoods

Angled

hoods

1

4

3

2

0

Rigid metal

Rigid metal

Rigid metal

Rigid metal

Rigid metal

100 ft. (30.5 m)

90 ft. (27.4 m)

80 ft. (24.4 m)

71 ft. (21.6 m)

63 ft. (19.2 m)

94 ft. (28.7 m)

84 ft. (25.6 m)

74 ft. (22.6 m)

65 ft. (19.8 m)

57 ft. (17.4 m)

Determine vent path:

Select route that will provide straightest and most direct

path outdoors.

Plan installation to use fewest number of elbows and turns.

When using elbows or making turns, allow as much room

as possible.

Bend vent gradually to avoid kinking.

Use as few 90° turns as possible.