Warning, Make power supply cord connection – Amana W10261420A Manuel d'utilisation

Page 11

Advertising
background image

What type of electrical
connection will you use?

Power Supply Cord:
Follow Option A instructions

Direct Wire:
Follow Option B instructions

Install strain relief

7

11

Remove terminal box cover

6

Using a

¹⁄₄” hex-head socket, nut driver or Phillips screwdriver,

remove terminal box cover. Retain for later use.

Install a UL Listed/CSA Approved strain relief. Check that the
screwheads are facing to the left when tightening conduit nut.
Strain relief may be provided with the power supply cord kit.

Option A, Power Supply Cord:

Route cord so that it does not touch dishwasher motor to lower

part of dishwasher tub. Pull cord through strain relief in terminal

bow.
Select UL Listed/CSA Approved twist-on wire connectors (not

included) rated to connect your household wiring to 16-gauge

dishwasher wiring.

Power Cord—Route cord
into terminal box

1

WARNING

Electrical Shock Hazard

Electrically ground dishwasher.

Connect ground wire to green ground connector
in terminal box.

Do not use an extension cord.

Failure to follow these instructions can result in
death, fire, or electrical shock.

Make Power Supply Cord Connection

Remove the green grounding screw and place
through the ring terminal of the green ground wire. Reattach
and tighten the green screw.

Ground

wire

Power Supply Cord—
Connect ground wire

2

Ground

wire

Washer

Ground

connector

Advertising