CONDENSER COIL
Prior to cleaning the condenser coil, disconnect the unit from power. Periodic cleaning of the
condenser coil will aid the heat transfer of the system and improve its efficiency. Cleaning is
recommended a minimum of every six months. The condenser coil is located behind the
back panel. Remove the back panel and locate the finned condenser coil. Use a soft bristled
brush to remove any collected dirt or debris on the coil. Use a vacuum cleaner or
compressed air to remove the loosened particles. Replace the back panel and reconnect the
power. Failure to clean the condenser coil can lead to performance loss and compressor
failure.

SERVICE

Any correspondence pertaining to these cabinets should be directed to the Service
Department. Be sure to include the cabinet model and serial number with any
correspondence.

Parts and Service: 800-388-5253

Nor-Lake, Incorporated