10 blower service or replacement – Napoleon Fireplaces EPI3C Manuel d'utilisation

Page 28

Advertising
background image

W415-1087 / A / 06.06.13

28

EN

A.

Turn off all electrical power to the appliance.

B.

Remove 4 screws from blower cover and slide the complete assembly forward.

C.

Detach the blower from the blower cover by removing 2 screws in the middle of the blower cover.

D.

When reconnecting electrical connections, ensure that they remain secure.

E.

To reinstall the blower assembly reverse these steps.

7.10 BLOWER SERVICE OR REPLACEMENT

BLOWER COVER

BLOWER

VARIABLE SPEED SWITCH

MICRO SWITCH

THERMAL DISC

FAN

POWER

CORD

THERMODISC