Blocked burner ports can cause an incorrect fl ame pattern, carbon deposits and delayed ignition. Phazer

tm

logs

glow when exposed to direct fl ame and provide a unique and realistic glowing effect. Use only certifi ed phazer

tm

logs available from your Napoleon® dealer.

Place log #1 onto the burner, centering it onto the
burner tray and pushing it as close to the rear wall
of the fi rebox as possible. Move logs # 2 and 3 into
position, lining up the studs located on the burner
with the holes on the bottom of the logs. Sit the notch
at the bottom of log #4 against the left outermost
grate post and position the top of the log into the
pocket provided on the rear log (#1).

The notch in log #5 should be pressed down onto
the skewering pin located at the end of the grate as
shown to prevent it from rocking.

6.4 GLASS / DOOR REPLACEMENT

A.

Place the door frame face down careful not to
scratch the paint.

B.

Center the gasketed glass inside the door frame
with the thick side of the gasket facing up.

C.

Bend the glass retainers located along the edge
of the door frame over the gasket holding the
glass in place. Careful not to break the glass.

!

WARNING

DO NOT USE SUBSTITUTE MATERIALS.

GLASS MAY BE HOT, DO NOT TOUCH GLASS UNTIL COOLED.

CARE MUST BE TAKEN WHEN REMOVING AND DISPOSING OF ANY BROKEN DOOR GLASS OR

DAMAGED COMPONENTS. BE SURE TO VACUUM UP ANY BROKEN GLASS FROM INSIDE THE

APPLIANCE BEFORE OPERATION.

DO NOT STRIKE, SLAM OR SCRATCH GLASS. DO NOT OPERATE APPLIANCE WITH GLASS

REMOVED, CRACKED, BROKEN OR SCRATCHED.

56.1A

6.5 LOG

PLACEMENT

GLASS

GASKET

DOOR
FRAME

GLASS
RETAINER