W415-0689 / C / 06.13.12

It is necessary to hard wire this appliance.
This appliance must be electrically connected and grounded in accordance with local codes. In the absence
of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI/NFPA 70-1996
national electrical code in the United States.

NOTE: During assembly, anti-oxidant compound was applied to all electrical connections. If replacing
the existing wire harness or disconnecting any connectors, it is highly recommended to re-apply anti-
oxidant compound to the relative connections.

6.0 ELECTRICAL INFORMATION

!

WARNING

RISK OF ELECTRIC SHOCK!

CONTROL AND VALVE OPERATE WITH 110V.

DO NOT USE THIS APPLIANCE IF ANY PART HAS BEEN UNDER WATER. CALL A QUALIFIED SER-

VICE TECHNICIAN IMMEDIATELY TO HAVE THE APPLIANCE INSPECTED FOR DAMAGE TO THE

ELECTRICAL CIRCUIT.

1 2

3 4

YELLOW

BROWN

W

+

,

7

E

B

L

$

&

.

IGNITOR
WIRE

IGNITOR

GAS

VALVE

SWITCH

CONTROL MODULE

110v

POWER

SUPPLY

GFI

(Ground Fault Interrupter)

G

R

O

U

N

D