3 venturi adjustment, 4 flame characteristics – Napoleon Fireplaces STARfire 52 - HDX52 Manuel d'utilisation

Page 42

Advertising
background image

42

W415-1276 / A / 05.09.14

EN

HDX52

NG

3/8” (9.5mm)

LP

7/16" (11mm)

This appliance has an air shutter that has been factory set open according
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

AIR
SHUTTER
OPENING

VENTURI
BURNER

ORIFICE

49.1

9.3 VENTURI

ADJUSTMENT

It’s important to periodically perform a visual check of the pilot and burner fl ames. Compare them to the
illustration provided. If any fl ames appear abnormal call a service person.

FLAME MUST ENVELOP
UPPER 3/8” (9.5mm) TO 1/2”
(12.7mm) OF FLAME SENSOR

PILOT

BURNER

ELECTRODE

FLAME

SENSOR

3/8” - 1/2”

(9.5mm - 12.7mm)

54.1B

9.4 FLAME

CHARACTERISTICS

MAXIMUM INPUT RATE

NG

55,000 BTU/HR

LP

55,000 BTU/HR