27

W415-1276 / A / 05.09.14

EN

IMPORTANT: The HDX52 requires a minimum inside enclosure height of 88" (2235mm), measured from the
bottom of the appliance. For temperature requirements, this area must be left unobstructed. It is recommended
that the enclosure be ventilated at the top and bottom to circulate the air.

88"

2235mm *

MINIMUM

ENCLOSURE

HEIGHT

41 7/8"

1064mm

MINIMUM

71 1/2"

1816mm

MINIMUM

PLUS RISE *

2" 51mm

5" 127mm

11 1/2"

292mm

MINIMUM **

MINIMUM

6"

152mm

COMBUSTIBLE

MATERIAL

TOP OF ENCLOSURE

BRICK

STEEL STUD

FRAMING

TOP OF

FIREPLACE

OPENING

0” (0mm) IF NON-

COMBUSTIBLE FINISHING

IS USED SUCH AS BRICK

AND STONE

NON-COMBUSTIBLE

MATERIAL

NOTE: JOINT COMPOUNDS AND TAPES
THAT ARE RESILIENT TO HEAT AND
CRACKING SHOULD BE USED WHEN
TAPING AND MUDDING SEAMS.

SAFETY SCREEN

** Within the appliance enclosure a 11 1/2" (292mm) clearance between the top of the vent pipe and combustible material
is required. All other clearance, including where the vent exits the enclosure are subject to 2" (51mm) to the sides and
bottom and 5" (127mm) to the top for horizontal and 1" (25mm) for vertical.

!

WARNING

RISK OF FIRE!

THE FRONT OF THE APPLIANCE MUST BE FINISHED WITH ANY NON-COMBUSTIBLE MATERIALS

SUCH AS BRICK, MARBLE, GRANITE, ETC., PROVIDED THAT THESE MATERIALS DO NOT COVER

THE APPLIANCE OPENING.

THE STEEL STUD FRAMING KITS WITH CEMENT BOARD PROVIDED MUST BE INSTALLED.