W415-1276 / A / 05.09.14

EN

* Within the appliance enclosure a 11 1/2" (292mm) clearance between the top of the vent pipe and
combustible materials is required. All other clearances within the enclosure, including where the vent pipe exits
the enclosure are subject to 2" (51mm) to the sides and bottom and 5" (127mm) to the top for horizontal and
1" (25mm) for vertical.

** See venting section.

IMPORTANT: THE FIRESTOP ASSEMBLY PROVIDED MUST BE USED WHEN THE VENT PIPES PASS
THROUGH ANY WALL OR ARE TERMINATED HORIZONTALLY.

71 1/2"

1816mm

2"

51mm

41 7/8"

1064mm

55 1/4"

1403mm

88"

2235mm

2"

51mm

5"

127mm

FIRESTOP

ASSEMBLY

11 1/2"

292mm

STEEL STUD

FRAMING

NON-COMBUSTIBLE

MATERIAL

0” IF NON-COMBUSTIBLE

FINISHING MATERIAL

IS USED SUCH AS

BRICK AND STONE.

65 7/8"

1673mm

ENCLOSURE

HEIGHT