Napoleon Fireplaces B35NT Manuel d'utilisation

Page 7

Advertising
background image

7

W415-1232 / B / 05.15.14

EN

2.3 GENERAL

INFORMATION

FOR YOUR SATISFACTION, THIS APPLIANCE HAS BEEN TEST-FIRED TO ASSURE ITS OPERATION AND

QUALITY!

This appliance is approved for bathroom, bedroom and bed-sitting room installations and is suitable for mobile
home installation.

No external electricity (110 volts or 24 volts) is required for the gas system operation.

Expansion / contraction noises during heating up and cooling down cycles are normal and are to be
expected.

RATES AND EFFICIENCIES

B35

B42

NG

LP

NG

LP

Altitude (FT)

0-4,500

0-4500

0-4,500

0-4500

Max. Input (BTU/HR)

20,000

20,000

25,000

25,000

Min. Inlet Gas Supply Pressure

4.5" (11mb) w.c.

11" (27mb) w.c.

4.5" (11mb) w.c.

11" (27mb) w.c.

Max. Inlet Gas Supply
Pressure

7" (17mb) w.c.

13" (32mb) w.c.

7" (17mb) w.c.

13" (32mb) w.c.

Manifold Pressure (Under Flow
Conditions)

3.5" (9mb) w.c.

10" (25mb) w.c.

3.5" (9mb) w.c.

10" (25mb) w.c.