0 adjustment, 1 pilot burner adjustment, 2 venturi adjustment – Napoleon Fireplaces B35NT Manuel d'utilisation

Page 42

Advertising
background image

42

W415-1232 / B / 05.15.14

EN

This appliance has an air shutter that has been factory set open according
to the chart below:

Regardless of venturi orientation, closing the air shutter will cause a more
yellow flame, but can lead to carboning. Opening the air shutter will cause a
more blue flame, but can cause flame lifting from the burner ports. The
flame may not appear yellow immediately; allow 15 to 30 minutes for the
final flame colour to be established.

AIR SHUTTER ADJUSTMENT MUST ONLY BE DONE BY A QUALIFIED
INSTALLER!

AIR
SHUTTER
OPENING

VENTURI
BURNER

ORIFICE

49.1

8.0 ADJUSTMENT

8.1 PILOT BURNER ADJUSTMENT

Check Pressure Readings:

Inlet pressure can be checked by turning screw (A) counter-clockwise 2 or 3
turns and then placing pressure gauge tubing over the test point. Gauge should
readas described on the chart below. Check with main burner operating on
“HI”.
Outlet pressure can be checked the same as above using screw (B). Gauge
should readas described on the chart below. Check with main burner operating
on “HI”.

AFTER TAKING PRESSURE READINGS, BE SURE TO TURN SCREWS CLOCKWISE FIRMLY TO RESEAL.
DO NOT OVERTORQUE.

Leak test with a soap and water solution.
Prior to pilot adjustment, ensure that the pilot
assembly has not been painted. If overspray or
painting of the pilot assembly has occurred
remove the paint from the pilot assembly, or replace. Fine emery cloth or sandpaper can be used to remove
the paint from the pilot hood, electrode and fl ame sensor.

39.5B

A

B

Pressure

Inlet

Outlet

Natural Gas

(inches)

Natural Gas

(millibars)

Propane

(inches)

Propane

(millibars)

7"

(MIN. 4.5")

3.5"

13"

(MIN. 11")

10"

17.4mb

(MIN. 11.2mb)

8.7mb

32.4mb

(MIN. 27.4mb)

24.9mb

8.2 VENTURI

ADJUSTMENT

VENTURI ADJUSTMENT CHART

FUEL

B35

B42

NG

1/16” (1.5mm)

1/16” (1.5mm)

LP

3/8” (9.5mm)

3/8” (9.5mm)

PILOT

IN

OUT

ADJ

HI

LO

VENT

B

A

ELECTRONIC

MILLIVOLT

Advertising