Safety chain – Indesit I5VMC1A(W)-FR Manuel d'utilisation

Page 17

Advertising
background image

GB

17

5. Fix the power supply cable in place by fastening
the cable clamp screw.
6. Close the terminal board cover by tightening the
screws V.

Connecting the supply cable to the mains
Install a standardised plug corresponding to the load
indicated on the data plate located on the appliance.
The appliance must be directly connected to the
mains using an omnipolar circuit-breaker with a
minimum contact opening of 3 mm installed between
the appliance and the mains. The circuit-breaker
must be suitable for the charge indicated and must
comply with current electrical regulations (the
earthing wire must not be interrupted by the circuit-
breaker). The supply cable must be positioned so
that it does not come into contact with temperatures
higher than 50°C at any point.

Before connecting the appliance to the power
supply, make sure that:
• The appliance is earthed and the plug is compliant

with the law.

• The socket can withstand the maximum power of

the appliance, which is indicated by the data
plate.

• The voltage is in the range between the values

indicated on the data plate.

• The socket is compatible with the plug of the

appliance. If the socket is incompatible with the
plug, ask an authorised technician to replace it.
Do not use extension cords or multiple sockets.

! Once the appliance has been installed,

the power supply cable and the electrical

socket must be easily accessible.

The cable must not be bent or

compressed.

!The cable must be checked regularly and

replaced by authorised technicians only.

! The manufacturer declines any liability

should these safety measures not be

observed.

*

Only available in certain models.

TECHNICAL DATA

Oven dimensions
(HxWxD)
Volume

57 l

Useful measurements

relating to the oven
compartment

width 42 cm

depth 44 cm
height 18 cm

Power supply voltage
and frequency

see data plate

Ceramic hob
Front Left

Back Left
Back Right
Front Right
Max. ceramic hob
consumption


1200 W

1700 W
1200 W
1700 W

5800W

Energy consumption for Natural
convection – heating mode: Static

;

Energy consumption for Forced
convection – heating mode:

Fan Oven;


EC Directives: 06/95/EC dated 12/12/06
(Low Voltage) and subsequent
amendments –

04/108/EC dated 15/12/04
(Electromagnetic Compatibility) and
subsequent amendments –
93/68/EEC dated 22/07/93 and

subsequent amendments –
2002/96/EC.
1275/2008 Stand-by/ Off mode

Safety Chain

! In order to prevent accidental tipping of the
appliance, for example by a child climbing onto the
oven door, the supplied safety chain MUST be
installed!
The cooker is fitted with a safety chain to be fixed by
means of a screw (not supplied with the cooker) to the
wall behind the appliance, at the same height as the
chain is attached to the appliance.
Choose the screw and the screw anchor according to
the type of material of the wall behind the appliance. If
the head of the screw has a diameter smaller than
9mm, a washer should be used. Concrete wall requires
the screw of at least 8mm of diameter, and 60mm of
length.
Ensure that the chain is fixed to the rear wall of the
cooker and to the wall, as shown in figure, so that
after installation it is tensioned and parallel to the
ground level
.

340x391x424mm

Regulation (EU) No 65/2014 supplemen-
ting Directive 2010/30/EU.
Regulation (EU) No 66/2014 implementing
Directive 2009/125/EC.
Standard EN 60350-1
Standard EN 50564.

ENERGY LABEL
and ECODESIGN

Standard EN 60350-2.

Advertising