30_ installation instructions

Flexible connector hookup

Installer: Inform the consumer of the location of the gas shut-off valve.

If your area requires a rigid pipe

hookup, contact a qualified

installer, service agency, or gas

supplier.

The gas shut-off valve should

be installed in an accessible

location in the gas piping,

external to the appliance, for the

purpose of turning on or shutting

off the gas to the appliance.

Step 3. Convert to lp gas (optional)

All new gas ranges are shipped from the factory set up to use natural gas. Any

Samsung gas range can be converted to use LP gas. Refer to page 82 in the

User Manual to contact a qualified service technician.
The conversion process should only be performed by a qualified LP gas installer.

Conversion instructions and LP orifices will be supplied with the LP conversion

kit. The conversion to LP requires all burner orifices to be changed (5 surface

burners and 2 oven burners).
In addition, the nozzle on the gas pressure regulator needs to be reversed. All

replaced orifices must be left with the consumer, including the instructions and

retrofit sizes and orifice indication.

BURNER ORIFICE SIZES AND

OUTPUT RATINGS

(LP Gas [Propane] 10 in WCP)

BURNER ORIFICE SIZES AND

OUTPUT RATINGS

(Natural Gas 5 in WCP)

Burner

Location BTU Rate

Orifice Size

[mm]

Burner

location

BTU Rate

Orifice size

[mm]

RF

14,500

In : 0.46 /

Out : 0.74

(2pcs)

RF

18,000

In : 0.70 /

Out : 1.27

(2pcs)

LF

11,500

1.04

LF

15,000

1.78

RR

4,000

0.62

RR

5,000

1.01

LR

7,500

0.83

LR

9,500

1.40

CTR

7,500

0.83

CTR

9,500

1.38

BAKE

15,000

1.15

BAKE

18,000

1.90

BROIL

11,500

1.02

BROIL

13,500

1.64

Pressure

Regulator

Adapter

Flex Connector

(6-ft max.)

Adapter

Gas Shut-Off Valve

0.5-in or 0.75-in Gas Pipe

Tubing Line to

Oven Burner

Control Valve

Tubing Line

to Cooktop

Control

Manifold

Gas Flow int

o Range

130521_(Install)_NX58F5700WS_DG68-00518A_EN+CFR.indb 30