installation requirements _23

INS
TALLA

TION

REQUIREMENT

S

gAS REQUIREMENTS

Provide adequate gas supply

This range is designed to operate at a pressure of 5 in (13 cm) of water

column on natural gas or 10 in (25 cm) of water column on LP gas

(propane or butane).

Make sure you are supplying your range with the type of gas for which it is

designed. Do not attempt to convert the appliance from the gas specified

in this manual to a different gas without consulting the gas supplier.

This range is convertible for use on natural or propane gas. If you decide to use

this range on LP gas, conversion must be made by a qualified LP installer before

attempting to operate the range.

For proper operation, the pressure of natural gas supplied to the regulator must

be between 5 in and 13 in (13 cm and 33 cm) of water column.

For LP gas, the pressure supplied must be between 10 in and 13 in (25 cm and

33 cm) of water column.

When checking for proper operation of the regulator, the inlet pressure must be

at least 1 in (2.5 cm) greater than the operating (manifold) pressure as given.

The pressure regulator located at the inlet of the range manifold must remain in

the supply line regardless of whether natural or LP gas is being used.

A flexible-metal appliance connector used to connect the range to the gas

supply line should have an I.D. of 0.5 in (1.3 cm) and be 5 ft (152 cm) in length

for ease of installation. In Canada, flexible connectors must be single-wall metal

connectors no longer than 6 ft (183 cm) in length.

Do not kink or damage the flexible metal tubing when moving the range.