2 | SAMLEX AMERICA INC.

!

caution!

1. The metal chassis of the inverter and the Grounding Terminal of the NeMA5-15r

outlet(s) are internally bonded (connected) to the Negative DC Input Terminal on the
inverter. In a vehicle / boat, the Negative Terminal of the battery is bonded to vehicle
chassis / boat’s hull. Hence, the metal chassis of the inverter and the AC loads will be
automatically grounded (bonded to the vehicle chassis / boat’s hull).

2. Please ensure that the Negative DC Input Terminal on the inverter or the battery Neg-

ative Terminal on the battery itself is bonded to earth Ground WHeN THe INVerTer IS
USeD oN LAND.

3. The Line and Neutral Terminals of the NeMA5-15r AC outlets are isolated from its

Grounding Terminal. Thus, the metal chassis of the AC loads and the metal chassis of
the inverter will also be isolated from the Line and Neutral. The Grounding Terminal
of the AC outlet is connected to the input section of the electronic Ground fault Pro-
tection Circuit on the Power Circuit board. Due to the above implementation, the volt-
age on the Neutral and Line Terminals of the AC outlet with respect to the chassis of
the inverter / chassis of the AC loads will be pulsing DC voltage with average DC value
of up to 50V (will read 75 VAC on AC scale of the Voltmeter because of pulsing nature
of DC voltage). Do not toucH tHe neutraL terminaL / neutraL conDuctorS!

4. Do not connect to AC distribution wiring where the Neutral is bonded to Ground. The

inverter will see this as abnormal condition of Ground fault and will shut down.

5. Do not use with Positive Grounded electrical Systems (the majority of modern

automobiles, rVs, trucks and boats use Negative Grounded electrical Systems).

6. observe correct polarity when connecting the DC input terminals of the inverter to the

battery. Connect Positive of the battery to the Positive input connector of the inverter
and the Negative of the battery to the Negative input terminal of the inverter. reverse
polarity connection will result in a blown fuse and may cause permanent damage to
the inverter. Damage due to reverse polarity is not covered under warranty.

7. This inverter will not operate high wattage appliances that exceed the output power

limit or the surge power limit.

8. Do not operate this inverter if it is wet.
9. Do not install in engine compartment – please install in a well-ventilated area.
10. This inverter is not tested for use with medical devices.