21

20

Parameter or

Specification

DAMP60

DAMP68

Feature/Function

Temperature

Measurement range

N/A

-40° to 752°F (-40° to 400°C)

Measurement accuracy

N/A

±(8% + 8 digits) from -40° to 4°F;

±(1.2% + 7 digits) from

4° to 32°F ; ±(1.2% + 6 digits)

from 32° to 212°F;

±(3% + 5 digits)@

≥212°F

Dielectric strength

6000V AC

6000V AC

(Voltage that dielectric can
withstand for 1 minute)

ETL safety rating

CAT III 600V

Clamp jaw

Type

Coil

Hall effect

Opening

1.1 in. (28mm)

1.2 in. (31mm)

Display

No. of digits

3-1/2

3-3/4

Maximum count

2000

4000

Analog bar graph

No

Yes

Backlight

Yes

Yes

Overload indication

Yes

Yes

Low battery indication

Yes

Yes

Ranging options

Auto

Auto or manual

Auto power off trigger

15 minutes

15 minutes

Data hold

Yes

Yes

True RMS measurement

No

Yes

Zero offset

No

Yes

Memory

Maximum value

No

Operating temperature

32° to 104°F (0° to 40°C)

32° to 104°F (0° to 40°C)

@<75% relative humidity

@<75% relative humidity

Maximum altitude

6562 ft. (2000m)

6562 ft. (2000m)

Power source

Two “AAA” batteries

Three “AAA” batteries

Dimensions

11.25 x 6.13 x 2.75 in.

11.38 x 6.25 x 2.75 in.

(286 x 156 x 70mm)

(289 x 159 x 70mm)

Weight

17 oz. (482g)

19 oz. (539g)

Note: All accuracy values stated at 73° F ± 4°F (23° ± 3°C) @<75% RH