Installation – ducting calculation sheet – Zephyr ZRM-E42BS Manuel d'utilisation

Page 7

Advertising
background image

5

Duct pieces

Total

Equivalent number
length x used =

3- 1/ 4” x 10”
Rect.,
straight

1 Ft. x ( ) =

Ft.

8” Round,
straight

1 Ft. x ( ) =

Ft.

3- 1/ 4” x 10”
Rect. 90

0

elbow

15 Ft. x ( ) =

Ft.

3- 1/ 4” x 10”
Rect. 45

0

elbow

9 Ft. x ( ) =

Ft.

3- 1/ 4” x 10”
Rect. 90

0

flat elbow

24 Ft. x ( ) =

Ft.

3- 1/ 4” x 10”
Rect.
wall cap
with damper

30 Ft. x ( ) =

Ft.

3- 1/ 4” x 10”
Rect. to
6” round
transition

5 Ft. x ( ) =

Ft.

3- 1/ 4” x 10”
Rect. to
6” round
transition
90

0

elbow

20 Ft. x ( ) =

Ft.

6” Round,
90

0

elbow

15 Ft. x ( ) =

Ft.

6” Round,
45

0

elbow

9 Ft. x ( ) =

Ft.

Ft.

7” Round,
straight

1 Ft. x ( ) =

Ft.

Subtotal column 1 =

Duct pieces

Total

Equivalent number
length x used =

6”- 8” Round
wall cap
with damper

30 Ft. x ( ) =

Ft.

Round

wall cap
with damper

30 Ft. x ( ) =

Ft.

7” or 8”

Round,

90

0

elbow

15 Ft. x ( ) =

Ft.

7” or 8”

7” or 8”

Round,

45

0

elbow

9 Ft. x ( ) =

Ft.

Ft.

Ft.

Ft.

6”- 8” Round,
roof cap

30 Ft. x ( ) =

Ft.

7” or 8”

Round,

roof cap

30 Ft. x ( ) =

Ft.

Subtotal column 2 =

Subtotal column 1 =

Total ductwork =

Maximum Duct Length:

For satisfactory air movement,

the total duct length of a 3 1/ 4” x 10” rectangular 6” or 7”
diameter round duct should not exceed 100 equivalent feet.

6” round to
3- 1/ 4” x 10”
rect.
transition

1 Ft. x ( ) =

Ft.

6” round to
3- 1/ 4” x 10”
rect.
transition
90

0

elbow

16 Ft. x ( ) =

Ft.

7” round to
3 1/ 4” x 10”
rect.
transition

8 Ft. x ( ) =

Ft.

7” round to
3- 1/ 4” x 10”
rect.
transition
90

0

elbow

23 Ft. x ( ) =

Ft.

Installation –

Ducting Calculation Sheet