Issue

Cause

What to do

After installation,
the unit doesn’t
work.

1. The power source is not turned ON.

1. Make sure the circuit breaker and the unit’s

power is ON.

2. The power line and the cable locking connector

is not connecting properly.

2. Check the power connection with the unit is

connected properly.

3. The switch board or control board wirings are

disconnected.

3. Make sure the wiring from the switch board

and control board are connected properly.

4. The switch board or control board is defective.

4. Change the switch board or control board.

Light works, but
blower is not
turning.

1. The blower cable is disconnected.

1. Check all wiring from the blower to be sure all

cables are connected properly.

2. The blower is defective, possibly seized.

2. Change the blower.

3. The thermally protected system detects if the

blower is too hot to operate and shuts the blower
down.

3. The blower will function properly after the

thermally protected system cool down.

4. Damaged capacitor.

4. Change the capacitor.

5. The switch board or control board is defective.

5. Change defective part.

The unit is
vibrating.

1. The blower is not secured in place.

1. Tighten the blower in place.

2. Damaged blower wheel.

2. Replace the blower.

3. The hood is not secured in place.

3. Check the installation of the hood.

The unit is
whistling.

1. The fi lter is not in the correct position.

1. Adjust the fi lters.

2. The duct pipe connections are not sealed or

connected properly.

2. Check the duct pipe connections to be sure all

connections are sealed properly.

The speed levels
of the blower
sound the same.

1. Using the wrong size of ducting.

1. Change the duct size to at least 6” round or

higher and change the duct type to rigid metal
rather than fl exable.

The blower is
working, but the
lights are not.

1. Defective halogen bulb.

1. Change the halogen bulb.

2. The light socket connector is loose.

2. Check the light socket connector.

3. The light bulb is loose.

3. Tighten the light bulb.

The hood is
not venting out
properly.

1. The hood might be hanging to high from the

cook top.

1. Adjust the distance between the cook top and

the bottom of the hood within 28” and 36”
range.

2. The wind from the opened windows or opened

doors in the surrounding area are affecting the
ventilation of the hood.

2. Close all the windows and doors to eliminate

the outside wind fl ow.

3. Blockage in the duct opening or ductwork.

3. Remove all the blocking from the duct work or

duct opening.

4. The direction of duct opening is against the wind.

4. Adjust the duct opening direction.

5. Using the wrong size of ducting.

5. Change the ducting to at least 6” or higher.

Mesh Filter is
vibrating.

1. Mesh fi lter is loose.

1. Change the mesh fi lter.

2. Filter spring clip is loose or broken.

2. Uninstall and reinstall fi lter, push up on fi lter

latch. Replace mesh fi lter if needed.