Installation – mounting the hood – Zephyr ZRM-E42BS Manuel d'utilisation

Page 11

Advertising
background image

9

1

2

Ceiling Joists

Wood Blocking

Top Support Frame

Support Frame Arm

Bottom Support Frame

Hood Body

Blower Housing

3

Mounting Screws
(pre-installed)

4

Installation –

Mounting the Hood

1. Determine mounting location on ceiling and temporarily tape paper template (included with hood) to ceiling.

Cut out internal shaded area of template to allow ducting and electrical to pass through. If necessary, add
wood blocking (min. 2” x 4”) to ceiling joists located behind the drywall to reinforce the mounting location*.
(FIG. A1) Secure (2) M6 x 1” wood screws to points A and B of the paper template. (FIG. B) Do not
completely tighten screws, leave approx. 1/4” exposed.

2. Remove screws securing top and bottom support frames together. Adjust support frame to accomodate the

desired hood height and re-assemble the frame using the previously removed screws (2 for each support
frame arm). (FIG. A3)

3. Lift support frame assemble up to the ceiling making sure the word “front” on the top support frame faces the

front of the hood where the controls will be located. (FIG. D) The key holes on the top support frame should
cover the wood screws previously installed in the ceiling. Slide support frame toward narrow end of key holes
to lock frame in place. Install the last (2) M6 x 1” wood screws with washers into the two remaining corners of
the top support frame to secure it to the ceiling. Tighten all screws.

4. Lift hood and align the (4) pre-installed mounting screws located on top of the Blower Housing (FIG. A4) with

the (4) key holes on the Bottom of Support Frame. (FIG. C) Slide hood towards the narrow end of key holes
to lock into place. Hand tighten each of the (4) screws with a screwdriver to secure hood to Bottom Support
Frame. Further secure bottom support frame to unit body by one M4 x 12 safety screw. (FIG. #, pg 10)

*Hood is intended to be mounted to a fi nished ceiling.

CAUTION: At least two installers are

required due to the weight and size of the
hood.

!

Bottom Support Frame

(secures to top of blower housing)

Key Holes

front - facing controls

back

FIG. A

FIG. C

FIG. B

Top Support Frame

Side

Front / Back

FIG. D

Advertising
Ce manuel est liée aux produits suivants: