Installation (continued), Set gas pressure, Set pilot flame – Wells HDCB1230G Manuel d'utilisation

Page 9: Adjust burner flame

Advertising
background image

INSTALLATION (continued)

7

SET GAS PRESSURE:

Gas pressure regulator is factory set.

SET PILOT FLAME:

Remove all burner control knobs, then remove the front panel.
Remove grates.

The pilot adjustments are near the control valve for each set of
burners.

Using a small, flat-blade screwdriver, turn the screw clockwise to

decrease the flame size, or counter-clockwise to increase the flame
size.

Adjust the pilot flame to 1/4” high. Test for operation: all sections
of the burner must light without undue delay. Drafty conditions may
require a higher flame to allow the pilot to remain lit.

Replace the grates, front panel and all knobs before returning the
unit to service.

ADjUST BURNER FLAME:

Remove all burner control knobs, then remove the front panel.
Remove grates and radiants.

Turn an individual burner on.

Loosen the locking screw on the shutter.

Turn the shutter to admit more or less air as required. Adjust the
air shutter until the flame is mostly blue in color.

Tighten the locking screw when finished. Replace tall grates and

radiants, the front panel and all knobs before returning the unit to
service.

Fig. 3 Adjustments

IMPORTANT:

Adjustments must be performed

by a qualified technician only.
IMPORTANT:

The appliance is shipped from
the factory equipped for natural
gas and adjusted for sea level
to 2000 feet elevation. For
conversion to LP / Propane,
or for operation above 2000
feet elevation, contact your
Authorized Wells Service
Agency.

LESS
FLAME

MORE
FLAME

MORE AIR

LOCKING
SCREW

LESS

AIR

SHUTTER

PILOT

FLAME

ADJUST

BURNER

FLAME

ADJUST

BURNER

CONTROL

KNOB

PILOT
FLAME
ADJUST

ON

OFF

IL2286