SYMPTOM

POSSIBLE CAUSE

SUGGESTED REMEDY

Pilot will not light

Gas supply off

Check main / unit gas valves

Air in lines

Turn pilot valve on. Attempt to light

pilot every 15 sec.

Pilot valve not on

Turn pilot valve on / adjust

Burners won’t light

Gas supply off

Check main / unit gas valves

Air in lines

Turn gas valve on. Attempt to light

pilot every 15 sec.

Pilot burner not lit

Turn off gas - allow unit to vent for 5

minutes. Turn gas back on and light

pilot

One burner assembly won’t

light

Control not on

Turn control knob to ON, Set to

desired setting when lit

Water in burner

Remove burner and dry thoroughly

Damaged gas control valve,

burner or other internal

component

Contact Authorized Wells Service

Agency for repairs

Portions of a burner won’t

light or have erratic flame

Burner wet or flame opening(s)

clogged

Clean and dry burner

Burner not hot enough

Temperature control not set

Adjust for desired temperature

Shutter or nozzle out of

adjustment

Contact qualified technician for

adjustment

Damaged gas control valve,

burner or other internal

component

Contact Authorized Wells Service

Agency for repairs

NOTE:

There are no user serviceable components in the burner assemblies or in the control valves. In all

cases of damage or malfunction, contact your Authorized Wells Service Agency for repairs.