Rinnai EX11C (RHFE-265FTA) Manuel d'utilisation

Page 5

Advertising
background image

Rinnai Corporation EX08C, EX11C Manual

5

Features

• Restarts automatically when ignition or combustion

fails.

• Clean Heating Forced Flue Type
• Easy Operation One-Touch Ignition
• Sensible Temperature Control Feature
• Comfortable Room Temperature Control and

Display

• Warm Air Outlet at Floor Level (keeps your feet

warm)

• Child Lock
• Room Temperature Setting Memory
• Clean the Air Filter - Indicator Lamp
• Energy Saving Economy Setting

• Humidifier Tray
• Air Flow Directional Louvers
• Direct Vent Easily Installed
• Proportional Heating Variable Capacity
• Hush! Quiet Operation
• Modern Design Minimizes Floor Space

Requirements

• Failure Message Display
• Two timer settings
• Dimmer
• Set back (setting a minimum temperature)
• Temperature settings in Fahrenheit or Celsius

See the installation instructions for the parts list of
the vent kit.

The “A” Vent Kit is included with the appliance.

The following flue manifold sizes are available:

Name Kit

No.

Fits

walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Flue Manifolds

EX08C EX11C

Natural Gas

Propane Gas

Natural Gas

Propane Gas

Minimum supply gas

pressure

4.5 in

(114 mm) W.C.

8.0 in

(203 mm) W.C.

3.5 in

(89 mm) W.C.

8.0 in

(203 mm) W.C.

Maximum supply gas

pressure

10.5 in

(267 mm) W.C.

13.0 in

(330 mm) W.C.

10.5 in

(267 mm) W.C.

13.0 in

(330 mm) W.C.

BTU/hour input

Low 3000 - High 8000

Low 5500 -

High 11000

Low 5700 -

High 11000

BTU/hour output

Low 4400 -

High 8800

Low 4560 -

High 8800

Low 2400 - High 6400

Appliance Specifications

Advertising