Extension Kit Installation (EX11C only)

INCORRECT
• Too many bends (limit is 2)

• Air intake hose is above

exhaust pipe

Extension through the top

AIR
INTAKE
HOSE

EXHAUST
PIPE

PIPE
CLAMP

PIPE
STOPPER A

CLAMP

Extension to the right (facing appliance)

CLAMP

PIPE
STOPPER A

PIPE
CLAMP

LONG
BENT
ELBOW

EXHAUST
ELBOW

AIR
INTAKE
HOSE

EXHAUST
PIPE

Extension to the left (facing appliance)

CLAMP

PIPE
STOPPER A

PIPE
CLAMP

LONG BENT ELBOW

EXHAUST
ELBOW

AIR
INTAKE
HOSE

EXHAUST
PIPE

If necessary, extension kits are available to extend the
exhaust line and air intake hose between the manifold
and the appliance.

(1) The maximum vent length is 13 feet (4 m) with 2

bends. The bent pipe attached to the appliance
does not count toward the max limit of 2 bends.

(2) For altitudes at or below 2000 feet (610 m), the

maximum vertical length is 8 feet (2.4 m). For
altitudes above 2000 feet (610 m), the maximum
vertical length is 5 feet (1.5 m).

(3) If the extension is longer than that shown in the

table below, the condensate may overflow the
condensation pan. Therefore, extensions
exceeding this length should drain to the outside
and sloped 3° downward.

(4) Do not allow any low points or sagging in the

exhaust line. Otherwise, condensate may block
the exhaust and affect combustion.

(5) Vent extensions installed in unconditioned air

space must be insulated with high temperature
insulation and must be accessible.

(6) Vent extensions must not be concealed per NFPA

54 and must be accessible allowing inspection and
repair. Decorative covers are available from
Rinnai.

These figures show the 3 possible ways that the
extension exhaust line and air intake hose may be
directed away from the appliance. All 3 views are from
behind the appliance. For your configuration,
position the air intake hose as shown.

8 feet (2.4 m) at or below 2000 feet (610 m)
5 feet (1.5 m) above 2000 feet (610 m)