Rinnai ENERGYSAVER EX22C Manuel d'utilisation

Page 5

Advertising
background image

Rinnai Corporation EX17C / EX22C Manual

5

Features

Natural Gas

Propane Gas

Minimum supply gas pressure

3.5 in (89 mm) W.C.

8.0 in (203 mm) W.C.

Maximum supply gas pressure

10.5 in (267 mm) W.C.

13.0 in (330 mm) W.C.

Appliance Specifications

Natural Gas Propane Gas

BTU/hour input

Low 8200
High 16700

Low 8200
High 16700

BTU/hour output Low 6560

High 13360

Low 6560
High 13360

EX17C

Natural Gas Propane Gas

BTU/hour input

Low 8200
High 21500

Low 8200
High 20700

BTU/hour output Low 6560

High 17200

Low 6560
High 16560

EX22C

• Restarts automatically when ignition or combustion

fails.

• Clean Heating Forced Flue Type
• Easy Operation One-Touch Ignition
• Programmable Thermostat
• Warm Air Outlet at Floor Level (keeps your feet

warm)

• Child Lock
• Room Temperature Setting Memory
• Clean the Air Filter - Indicator Lamp
• Energy Saving Economy Setting
• Humidifier Tray

• Air Flow Directional Louvers
• Direct Vent Easily Installed
• Proportional Heating Variable Capacity
• Hush! Quiet Operation
• Modern Design Minimizes Floor Space

Requirements

• Fault Code Message Display
• Timers 1 and 2
• Dimmer
• Set back (setting a minimum temperature)
• Temperature settings in Fahrenheit or Celsius

See the installation instructions for the parts list of
the vent kit.

The “A” Vent Kit is included with the appliance.

The following flue manifold sizes are available:

Name Kit

No.

Fits

walls

S Vent Kit

FOT-150

3 - 4 1/2 in (75 - 115 mm)

A Vent Kit

FOT-151

4 1/2 - 9 1/2 in (115 - 240 mm)

B Vent Kit

FOT-152

9 1/2 - 15 3/4 in (240 - 400mm)

C Vent Kit

FOT-153

15 3/4 - 23 5/8 in (400 - 600 mm)

D Vent Kit

FOT-154

23 5/8 - 31 1/2 in (600 - 800 mm)

Flue Manifolds

Advertising