Extension kit installation – Rinnai ENERGYSAVER EX22C Manuel d'utilisation

Page 24

Advertising
background image

24

Rinnai Corporation EX17C / EX22C Manual

Extension Kit Installation

CASE A

• Extension lines are through the side panel of the

appliance.

• It is not possible to position the extension lines

through the other side panel of the appliance.

• One elbow is shown. One additional elbow may be

added.

• Instructions (1)-(6) must be followed.

Plastic Tie

Air Intake Hose

Exhaust Line

Pipe
Stopper A

Pipe Clamp

CASE B

• Extension lines are through the top panel of the

appliance above where the air intake enters the
appliance.

• Two elbows are shown. No additional elbows may

be added.

• Instructions (1)-(6) must be followed.

Plastic Tie

Air Intake Hose

Exhaust Line

Pipe Stopper A

Pipe Clamp

• Extension lines are through the top panel of the

appliance above where the exhaust exits the appli-
ance.

• No elbows are shown. Two additional elbows may

be added.

• Instructions (1)-(6) must be followed.

CASE C

Plastic Tie

Exhaust Line

Pipe Stopper A

Pipe Clamp

Air Intake Hose

If necessary, extension kits are available to extend the
exhaust line and air intake hose between the manifold
and the appliance.

(1) The maximum vent length is 13 feet (4 m) with 2

bends. The bent pipe attached to the appliance
does not count toward the max limit of 2 bends.

(2) Maximum vertical length allowed is 10 feet (3 m).
(3) If the extension is longer than 10 feet (3 m), the

condensate may overflow the condensation pan.
Therefore, extension exceeding this length should
drain to the outside and sloped 3° downward.

(4) Do not allow any low points or sagging in the

exhaust line. Otherwise, condensate may block the
exhaust and affect combustion.

(5) Vent extensions installed in unconditioned air space

must be insulated with high temperature insulation
and must be accessible.

(6) Vent extensions must not be concealed per NFPA

54 and must be accessible allowing inspection and
repair. Decorative covers are available from Rinnai.

These figures show the 3 possible ways that the
extension exhaust line and air intake hose may be
directed away from the appliance. All 3 views are from
behind the appliance. For your configuration,
position the air intake hose as shown.

INCORRECT
• Too many bends (limit is 2)

• Air intake hose is above

exhaust pipe

Advertising
Ce manuel est liée aux produits suivants: