Adjust gas pressure settings – Rinnai Rimal Energysaver Gas Direct Vent Wall RHFE-263FA II Manuel d'utilisation

Page 5

Advertising
background image



Rinnai Corporasion RHFE-263FAConversion Manual

Adjust Gas Pressure Settings

The LED display turns blank and the unit

returns to the normal off mode. While

programming the correct low fire and high fire

gas pressure settings, do not adjust gas

pressure on this appliance using the screw on

top of the gas valve.

11. Press the ON/OFF button to operate the

appliance.

12. Press the SW1 switch. The LED will display “78”

or “7” followed by a symbol.

13. Press the SW1 switch again to change to the low

pressure mode. The LED will display “PL”.

14. Compare the pressure reading on the manometer

to the desired manifold test pressure (low) for

your gas type and altitude. If necessary adjust

the low fire pressure using the ▲ and ▼ buttons.

15. Press the Economy button. The LED will display

“18” indicating that the low pressure has been

recorded into memory.

16. Press the SW1 switch

TWICE. This puts the

appliance into the high fire mode. The LED will

display “PH”.

17. Compare the pressure reading on the manometer

to the desired manifold test pressure (high) for

your gas type and altitude. If necessary adjust

the high fire pressure using the ▲ and ▼ buttons.

18. Press the Economy button to enter the high fire

pressure into memory. The LED display will

display “78”. If the LED shows any thing other

than “78” call Rinnai Technical Support at 1-800-

621-9419 for assistance.

19. Press the ON/OFF button again. The LED

display turns blank and the appliance returns to

the normal OFF mode.

20. Remove manometer and install Allen head

screws. Operate the unit and

check the normal operating sequence

visually inspect the flame

check for gas leaks at the test points

Normal Operating Sequence
When you press the ON/OFF button, the LED display

will illuminate, the combustion fan will begin to run,

and the spark will ignite the main burner.
This heater has an automatic ignition system. When

the main burner has lit, the combustion lamp will glow

red, and the spark will stop.

Visual Inspection of Flame
Check that the burner flames are operating normally.

The flame can be seen through the circular window

through the louvers.
When operating normally the burner flame should

appear as long, clear, blue, stable, streaks. Yellow

flames or an orange color is abnormal and

maintenance is required.

Final Assembly
1㧚Install the front panel and bottom cover.
2㧚Place the conversion plate (label) on the front

cover.

NORMAL

ABNORMAL

Flame Rod

Yellow flames or

orange color

Long, clear, blue,

stable flames

Flame Rod

Do not touch the areas at or near the glass panel or

exhaust. These areas become very hot and could

cause burns.