Adjust Gas Pressure Settings

1. Turn off the gas and the power supply.
2. Hold both ends of the bottom cover (undercover

assembly) and pull toward you to remove the

cover. Cover snaps in place.

3. Remove the 7 screws that hold the front panel

and the louver assembly to remove panel from

the unit. Pull the panel out at the bottom about 4

inches (100 mm) and lift up over clips that hold it

in place at the unit’s top.

4. Remove two test point screws (1/8 NPT tap) with

3/16 Allen wrench and attach the manometer to

both test ports. Both ports must be used in order

to measure the differential pressure. Ensure that

the manometer is properly calibrated.

5. Turn on the gas and power supply to the

appliance. With the unit in the Off position, press

the SW1 switch at the top of PC board until it

beeps.

6. Select the correct code on the LED display using

▲ and ▼ buttons:

High altitude is above 2000 ft (610 m).

L1: Propane gas at low (sea level) altitude

L2: Propane gas unit at high altitude

A1: Natural gas at low (sea level) altitude

A2: Natural gas unit at high altitude

7. Press the SW1 test button to record the gas type

code into memory. The LED will display “F1”. If

not shown, use the ▲ and ▼ buttons to obtain

“F1”.

8. Press the SW1 switch to enter this code into

memory.

9. The LED will display the temperature scale. Use

the ▲ and ▼ buttons to select the Fahrenheit or

Celsius scale.

10.Press the SW1 switch to enter the temperature

scale into memory.

Test

points

SW1

Do not touch any other areas on the PC board

besides the “SW” switches while power is supplied

to the appliance. Parts of the PC board are

supplied with 120 volts AC.

LED