Installation – Napoleon Fireplaces GSS36N Manuel d'utilisation

Page 5

Advertising
background image

5

W415-0369 / E / 02.16.07

INSTALLATION

This fi replace is intended for installation on an outdoor patio
or in your yard. It must never be installed inside the warm air
envelope of your structure.
It is highly recommended that this fi replace be installed in a
“sheltered” area. Direct wind will cause an erratic fl ame and
possible pilot or main burner outage.
An erratic fl ame could also lead to excessive carboning
(black soot), this condition is not a safety issue but is visu-
ally undesirable.
Typical installation may include covered patio, screened
porch, gazebo or an outside the wall of a house.*
NOTE: Ensure the area has adequate ventilation.

Sides, back, bottom & top

0 inches

Recessed 13¾

inches

Top of unit to ceiling

48”

It is recommended that the walls of the fi replace enclosure be
fi nished. This would ensure that clearance to combustibles
is maintained within the cavity.

COMBUSTION & VENTILATION AIR

CLEARANCE TO COMBUSTIBLES

NOTE: If the unit is installed using a propane cylinder

as a source of fuel, the cylinder must be retained. A
stand for a standard 20lb cylinder is available from your
NAPOLEON® Dealer.

1. Move the fi replace into position and secure using the

nailing tabs and/or secure to the fl oor through the ¼”ø holes
located at either end of the base.

2. Install rigid black pipe, 1/2” type-L copper tubing or, if

local codes permit, a 3/8” fl ex connector and shutoff valve
to the gas line and the fi replace gas valve. Seal and tighten
securely. An adapter fi tting is required between the gas valve
and the copper tubing or fl ex connector.

DO NOT KINK FLEX CONNECTOR.

3. Check for gas leaks by brushing on a soap and water

solution.

DO NOT USE OPEN FLAME.

4. For ease of accessibility, an optional remote wall switch

may be installed in a convenient location. Route a 2 strand,
solid core millivolt wire through the electrical hole located at
the bottom left side of the unit. The recommended maximum
lead length depends on wire size:

WIRE SIZE

MAX. LENGTH

14gauge

100

feet

16gauge

60 feet

18gauge

40 feet

Attach the two leads to terminals 1 and 3 located on the
gas valve.

Do not connect either the wall switch, thermostat or gas
valve to electricity (110 volts).

FIGURE 3

GAS INSTALLATION

FIGURE 4

* If installing a propane fi replace the propane cylinder

must always be on the exterior of such a structure.

FIGURE 2

Advertising